4th WCSET-2015 at Japan
Civil Engineering:
Title:
Seismic response of a structure retrofitted with fluid
viscous dampers in core wall – An analytical study
Authors:
Avinash A. R., Sachin Kuckian, Mohamed Parvez, Kiran
Kamath
Abstract: The
present study investigates the seismic behavior of multi
storey building retrofitted with damping devices located
within the lateral load resisting elements (core wall).
The study concentrates on a retrofitting strategy with
passive energy dissipation devices known as Fluid
Viscous Dampers (FVDs) in diagonal configuration. A 3D
model of a twenty seven storey core wall structure is
developed in SAP 2000® (commercial software for
structural analysis and design). FVDs are provided in
cut outs of core wall which are located in three
consecutive storeys. The cut out locations are varied
depending on their relative positions. Relative position
is the ratio of total height of the structure to the
upper edge of topmost cutout. Time history and response
spectrum analysis were used in the study. Seismic
response of the structure in terms of roof deflection
and roof acceleration is compared for the structure with
and without dampers by varying relative positions of the
cutouts. Results indicate that dampers provided at lower
cutouts i.e. for higher value of relative position there
is a significant reduction in seismic response.
Keywords: Seismic response;
Retrofitting; Core wall; Displacement; Acceleration;
Cutouts
Pages:
230-236