Int. J. Advanced Structures & Geotechnical Engineering
ISSN 2319-5347, ISI Impact Factor: 0.763
VOLUME 05 NO. 01 JULY 2016:
Title:
Seismic response of a structure retrofitted
with fluid viscous dampers in core wall – An analytical
study
Authors:
Avinash A. R., Sachin Kuckian, Mohamed Parvez,
Kiran Kamath
Abstract:
The present study investigates the seismic
behavior of multi storey building retrofitted with
damping devices located within the lateral load
resisting elements (core wall). The study concentrates
on a retrofitting strategy with passive energy
dissipation devices known as Fluid Viscous Dampers
(FVDs) in diagonal configuration. A 3D model of a twenty
seven storey core wall structure is developed in SAP
2000® (commercial software for structural analysis and
design). FVDs are provided in cut outs of core wall
which are located in three consecutive storeys. The cut
out locations are varied depending on their relative
positions. Relative position is the ratio of total
height of the structure to the upper edge of topmost
cutout. Time history and response spectrum analysis were
used in the study. Seismic response of the structure in
terms of roof deflection and roof acceleration is
compared for the structure with and without dampers by
varying relative positions of the cutouts. Results
indicate that dampers provided at lower cutouts i.e. for
higher value of relative position there is a significant
reduction in seismic response.
Keywords:
Seismic response, Retrofitting, Core wall,
Displacement, Acceleration, Cutouts
Pages:
23-29